Add to Cart
Mr. Stephen Sun (Sales & Co-founder)
Email: info@metery-tech.com, sales@meterytech.com
----------------------------------------------------------------------------------------
www.meterytech.com
Payment: T/T, Western Union, Paypal
Picture of BSP NPT Vortex flow meter Steam compensation vortex flowmeter
Installation Field of Users
Parameter of vortex flow meter | |||||
Measured Mediums | liquids, gases and steams (NOTE: the mediums should be unidirectional or can be seen as unidirectional.) | ||||
When the dryness of saturated steams ≥85%, they can be seen as unidirectional. | |||||
Temperature of Mediums | - 40°C ~ + 350°C | ||||
Pressure of Mediums | 1.6MPa, 2.5MPa, 4.0 MPa | ||||
For over 4.0 MPa, please contact us freely, for it needs special customization. | |||||
Accuracy | 1.0; 1.5 | ||||
Span Rate | 1:8 ~ 1:30(compared with the standard atmospheric pressure) | ||||
1:8 ~ 1:40 ( compared with the nominal temperature water) | |||||
Flow Range | Liquids: 0.4 ~ 7.0 m/s | ||||
Gases: 4.0 ~ 60.0 m/s | |||||
Steams: 5.0 ~ 70.0 m/s | |||||
Nominal Diameter | DN 25, 40, 50, 65, 80, 100, 125, 150, 200, 250,300 mm | ||||
Materials | 1Cr18Ni9Ti | ||||
Reynolds No. | Normally, 2*104 ~ 7*106 | ||||
Resistance Coefficient | Cd ≤ 2.6 | ||||
Licensed Vibration Acceleration | LUGB type ≤ 0.2g | ||||
Class of Protection | IP65 | ||||
Class of Explosion-Proof | Intrinsically Safe Explosion-Proof: Exia II CT2 ~ CT6 | ||||
Explosion Suppression: Exid II CT4 | |||||
Conditions of Surroundings | Temperature of Surroundings: | Non-Explosion Proof Surroundings: -40°C~ +55°C | |||
Explosion-Proof Surroundings: -20°C~ +55°C | |||||
Relative Humidity: | ≤ 85% | ||||
Atmospheric Pressure: | 86 ~ 106 kPa | ||||
Power Supply | Non-Explosion Proof Type | Pulse type: | +12 VDC ( the output current is 4 ~ 20mA) | ||
Current type: | +24 VDC ( the output current is 4~ 20mA) | ||||
Explosion-Proof Type | Current type: | +24 VDC ( the output current is 4~20mA) | |||
Output Signal | Frequency pulse signal 2~3000Hz, low level voltage ≤1V, high level voltage ≥ 6V | ||||
Two-wire system 4 ~ 20mA signal (isolation output), load ≤ 500Ω. |
Measuring range of vortex flow meter MT100VX
Measure range of vortex flow meter | ||
Diameter (mm) | Water | Gases in the Normal Temperature and Pressure |
Range of Standard Measurement (m3/h) | Range of Standard Measurement (m3/h) | |
25 | 2 ~ 16 | 8~60 |
32 | 1.5~15 | 14~100 |
40 | 3~30 | 18~180 |
50 | 4~40 | 30~300 |
65 | 6~60 | 50~500 |
80 | 13~130 | 70~700 |
100 | 20~200 | 100~1000 |
125 | 36~360 | 150~1500 |
150 | 50~500 | 200~2000 |
200 | 100~1000 | 400~4000 |
250 | 150~1500 | 600~6000 |
300 | 200~2000 | 1000~10000 |
Workshop and warehouse
Electrical Wiring Diagram
Installation cautions
Pipes must be fully filled with liquids, it is essential that pipes remain fully filled at all times, other ise flow rate
indications may be affected and measurement errorsmay be caused.
Avoids air bubbles. if air bubbles enter a measurement pipe, flow rate indications may be affected and measurement
errors may be caused.
International certificates of our flowmeter
In order promote our qualification and credit for servicing our users, we apply and pass the related field authority certificates.
Packing for Shipment
At your service
Our principle is "Reputation from Services&Quality is the lifeline of enterprise", so besides our product, satisfactory
services is our another competitive hand.
Contacts
Mr. Stephen Sun (Sales & Co-founder)
Email: info@metery-tech.com, sales@meterytech.com
----------------------------------------------------------------------------------------
www.meterytech.com
Payment: T/T, Western Union, Paypal